Aion Biogenx
Scanned from the vial

Certificate of analysis

This is the release record for the lot printed on the label you scanned. Every figure below was measured on material drawn from that lot, and the method sits beside the result so your QA lead can check it against an incoming specification.

Lot record

One lot, one certificate.

A catalog average tells you what a supplier hopes is in the vial. This tells you what was in this one. Retain samples for the lot are held for two years from the release date, and a re-test against them can be requested through your account.

Question about this lot? Quote the lot number and the SKU.

Lot 26-0714
Released 14 Jul 2026
Semaglutide 5 mg AB-SEMA-5
IdentityConformsMS
Assay purity99.4 %HPLC
Water content2.8 %Karl Fischer
Residual solventsWithin limitGC headspace
Bacterial endotoxinWithin limitLAL
AppearanceWhite lyophilised cakeVisual
Fill5 mg per vialGravimetric
Storage2 to 8 °C, darkSpecification
Released 14 Jul 2026 Signed by the QC lead

Sample record, shown for illustration. Production lots resolve to their own certificate under this same address.

Handling

Before you reconstitute.

Store the sealed vial at 2 to 8 °C, protected from light. Brief excursions to room temperature in transit are covered by the stability data for this lot.

Refrigerate after reconstitution and use within the window your own protocol sets. Aion Biogenx publishes specification, not a use protocol.

The lot, the expiry and this address are printed on the label. If the printed lot does not match the record above, stop and contact us before use.

Back to the catalog